Yazaki Energy Systems Inc


Yazaki - Gas Fired Double-Effect Chiller-Heaters


Gas Fired Double-Effect Chiller-Heaters

CH-K Series: 30, 40, 50, 60, 80, 100 RT Cooling with Standard Heating Capacities


Specifications




Specifications - Imperial Units

These models use the "G" control package
 
Model
CH-K
30
40
50
60
80
100
Capacity1 Cooling High Fire
MBTUh
360 480 600 720 960 1200
Low Fire
MBTUh
270 360 450 454 672 840
Heating High Fire
MBTUh
271
362
452
544
725
976
Low Fire
MBTUh
204
271
339
342
507
683
Cooling C.O.P 1.1 1.02
Capacity Control (High / Low) 100% / 75% 100% / 63% 100% / 70%
Chilled / Hot Water2 Cooling
°F
54.5 Inlet / 44.6 Outlet
Heating Inlet
°F
123.3 123.6 122.9
Outlet
°F
131.0
Rated Water Flow
GPM
72.6 96.8 121 145.1 193.5 241.9
Evaporator Pressure Loss2
PSI
9.22 11.42 14.12
Maximum Operating Pressure
PSI
85.3
Water Retention Volume
Gal
18 23 29 34 64 81
Cooling Water2 Total Heat Rejection
MBTUh
631
842
1052
1264
1685
2176
Inlet Temperature
°F
85.1
Outlet Temperature
°F
95.7 95.5 95.9
Rated Water Flow
GPM
120.8
161.0
201.3
241.5
322.0
402.5
Condenser / Absorber Press. Loss2
PSI
9.92
12.82
9.22
14.92
Maximum Operating Pressure
PSI
85.3
Water Retention Volume
Gal
38.3 47.6 62.1 78.2 108.6 141.1
Electrical3 Power Supply 208V or 230V / 60 Hz / 3-Phase
Consumption3
Watts
9003 12003 12503 16003 18003 25003
Minimum Circuit Amps
Amps
14.0
15.9
18.0
18.6
MOCP – Max. Fuse Size
Amps
15 20
Burner Burner Input High Fire1
MBTUh
3271 4361 5451 6551 8731 11761
Low Fire1
MBTUh
2451 3271 4091 4131 6111 8231
Supply Gas Pressure
Inches W.C.
5 – 10.5" w.c. 7 – 10.5" w.c.
Type Forced Draft with Category I Venting
Gas Dedicated: Natural or Propane. Not convertible.
Ignition Type Intermittent or Interrupted Spark
Flame Detection Optical or UV Scanner
Construction4 Dimensions Width
Inches
57.5 70.1 72.4
Depth5
Inckes
60.65 70.15 74.85
Height4
Inches
79.14 94.54
Height w/ Vent
Cap Installed
Inches
96.14 111.14
Weight Dry
Lbs
3950 4230 5090 5310 7500 8600
Operating
Lbs
4475 4860 5990 6330 9105 10355
Cabinet NEMA 3R, Silver Metallic Pre-Painted Hot Dip Zinc-Coated Sheet Steel
Noise Level
dB(A)
63 62 64 67
Piping Chilled / Hot Water
Inches
2 NPT 2-1/2 NPT 3 NPT 4 Flanged
Cooling Water
Inches
2-1/2 NPT 3 NPT 5 Flanged
Gas
Inches
1-1/2 NPT 2 NPT 2-1/2 NPT
Flue Diameter
Inches
6.3 7.1
Notes:
  1. Fuel input is based on the Higher Heating Value of gas. Burner efficiency = 83%.
  2. Pressure Loss ratings are +/- 10%.
  3. Power Consumption does not include external pumps or cooling tower fan motors.
  4. "Height" does not include level bolts, but "Height with Vent Cap" includes both vent cap and the level bolts.
  5. "Depth" does not include Junction Box. Add 3.9" to Depth Dimension to include Junction Box.
  6. Specifications are based upon water in all fluid circuits and fouling factor of 0.0005 ft²-hr-°F/Btu.

Specifications - Metric Units (all values converted from Imperial Units)

These models use the "G" control package
 
Model
CH-K
30 40 50 60 80 100
Capacity1 Cooling High Fire
kW
106
141
176
211
281
352
Low Fire
kW
79
106
132
133
197
246
Heating High Fire
kW
80
106
133
159
212
286
Low Fire
kW
60
80
99
100
149
200
Cooling C.O.P 1.1 1.02
Capacity Control (High / Low) 100% / 75% 100% / 63% 100% / 70%
Chilled / Hot Water2 Cooling
°C
12.5 Inlet / 7.0 Outlet
Heating Inlet
°C
50.7
50.9
50.5
Outlet
°C
55.0
Rated Water Flow
l/sec
4.6 6.1 7.6 9.2 12.2 15.3
Evaporator Pressure Loss2
kPa
63.42
78.62
97.22
Maximum Operating Pressure
kPa
588
Water Retention Volume
liters
68 87 110 129 242 307
Cooling Water2 Total Heat Rejection
kW
185
247
308
370
494
638
Inlet Temperature
°C
29.5
Outlet Temperature
°C
35.4 35.3 35.5
Rated Water Flow
l/sec
7.6 10.2 12.7 15.2 20.3 25.4
Condenser / Absorber Press. Loss2
kPa
68.32 88.32 63.42 1032
Maximum Operating Pressure
kPa
588
Water Retention Volume
liters
145 180 235 296 411 534
Electrical3 Power Supply 208V or 230V / 60 Hz / 3-Phase
Consumption3
Watts
9003 12003 12503 16003 18003 25003
Minimum Circuit Amps
Amps
14.0 15.9 18.0 18.6
MOCP – Max. Fuse Size
Amps
15 20
Burner Burner Input High Fire1
kW
961 1281 1601 1921 2561 3451
Low Fire1
kW
721 961 1201 1211 1791 2421
Supply Gas Pressure
kPa
1.25 - 2.6 1.75 - 2.6
Type Forced Draft with Category I Venting
Gas Dedicated: Natural or Propane. Not convertible.
Ignition Type Intermittent or Interrupted Spark
Flame Detection Optical or UV Scanner
Construction4 Dimensions Width
mm
1460 1780 1840
Depth5
mm
15405 17805 19005
Height4
mm
20104 24004
Height w/ Vent
Cap Installed
mm
24404 28204
Weight Dry
kg
1792 1919 2309 2409 3402 3901
Operating
kg
2030 2204 2717 2871 4130 4697
Cabinet NEMA 3R, Silver Metallic Pre-Painted Hot Dip Zinc-Coated Sheet Steel
Noise Level
dB(A)
63 62 64 67
Piping Chilled / Hot Water
Inches
2 NPT 2-1/2 NPT 3 NPT 4 Flanged
Cooling Water
Inches
2-1/2 NPT 3 NPT 5 Flanged
Gas
Inches
1-1/2 NPT 2 NPT 2-1/2 NPT
Flue Diameter
mm
160 180
Notes:
  1. Fuel input is based on the Higher Heating Value of gas. Burner efficiency = 83%.
  2. Pressure Loss ratings are +/- 10%.
  3. Power Consumption does not include external pumps or cooling tower fan motors.
  4. "Height" does not include level bolts, but "Height with Vent Cap" includes both vent cap and the level bolts.
  5. "Depth" does not include Junction Box. Add 3.9" to Depth Dimension to include Junction Box.
  6. Specifications are based upon water in all fluid circuits and fouling factor of 0.0005 ft²-hr-°F/Btu.